Terms and Conditions
Terms and Conditions
Environmental and Quality Assurance
Quality Assurance Procedure
Terms and Conditions
HOW TO ORDER
A complete part number must be specified to place an order. This must include the model number, outline number and connector type. Orders may be placed with the factory or its local representative. A written purchase order is required to enable the factory to proceed with the manufacture and shipment of the items requested. Frequency optimization over reduced bandwidth is available at little or no extra charge. Custom outlines are also available.
TERMS & CONDITIONS
All sales are subject to Pulsar Microwave Corporation
standard terms and conditions as stated herein, unless specifically
agreed to otherwise by the factory. Shipments are F.O.B. Clifton,
New Jersey, U.S.A. Payment terms are NET 30 for customers with
approved credit. Shipments will be made to all others on a C.O.D.
basis or with payment in advance, at our discretion.
DELIVERY
When a carrier is not specified by the customer at the time that an
order is placed, shipment will be made via UPS-BLUE service.
PACKING AND PACKAGING
Packing and packaging normally supplied is to "best commercial
standards". Packing to military requirements or for export is available
upon request, at an extra charge to be quoted by the factory.
INSURANCE
Unless requested otherwise at the time an order is placed, all
shipments will be insured at full value. The insurance charge will be added to
the invoice.
TEST DATA AND SOURCE INSPECTION
Requests for test data and customer source inspection must be
made at the time an order is placed. There will be additional
charges for these services as quoted by the factory.
WARRANTY
Pulsar Microwave Corporation warrants that
the components to be delivered shall, at the time of delivery,
be free from defects, in material and workmanship. Pulsar's
obligation under this warranty is limited to the repair or replacement
of the defective parts; all freight costs to and from Pulsar's
plant will be paid by the buyer. This warranty shall remain
in effect for the period of one year from the date of shipment.
Pulsar shall have no liability for special, incidental or consequential
damages resulting from improper use, negligence or accident.
Complete or partial disassembly of the components will void
this warranty.
CHANGE OF PRODUCT
SPECIFICATIONS
Catalog specifications are subject to change at any time. Pulsar
Microwave Corporation reserves the right to discontinue
items without prior notice.
Environmental & Quality Assurance
Pulsar's products are designed and manufactured following our stringent in house quality assurance procedures. They are capable of withstanding without damage the following environmental screening tests as defined by MIL-Std-202.
| Test | MIL-Std-202 | Description | Package Style | |
|---|---|---|---|---|
| Hermetic | Non- Hermetic |
|||
| Operating Temp. | -- | -- | -55 to +100°C | -25 to +80°C |
| Storage Temp. | -- | -- | -55 to +150°C | -55 to +150°C |
| Altitude | Method 105/E | 150,000 feet | As Defined | As Defined |
| Humidity | Method 106 | 90% Relative Humidity, 65°C |
As Defined | Not Applicable |
| Thermal Shock | Method 107/B | -55°C to +85°C | As Defined | As Defined |
| Fine Leak | Contact Pulsar for Details | -- | As Defined | Not Applicable |
| Gross Leak | At Extra Cost | -- | As Defined | Not Applicable |
| Drop | Method 203 | Random, 45 Minutes | As Defined | As Defined |
| Vibration | Method 204/D | 10 to 2000 Hz, 20 G's, 12 Hours |
As Defined | As Defined |
| Solderability | Method 208 | 95% Coverage | As Defined | As Defined |
| Solder Heat | Method 210/B | 260°C, 10 Seconds | As Defined | As Defined |
| Terminal Strength | Method 211/A | 2 lbs., 10 Seconds | As Defined | As Defined |
| Terminal Fatigue | Method 211/C | 1 lb., 3 cycles | As Defined | As Defined |
| Mechanical Shock | Method 213/I | 100 G's, 6 ms | As Defined | As Defined |
| Random Vibration | Method 214/2F | 15 Minutes | As Defined | As Defined |
| Solvent Resistance | Method 215 | 15 Minutes | As Defined | As Defined |
Quality Assurance Procedure
Pulsar Microwave Corporation Employs stringent quality assurance policies and procedures which are defined by our in house Quality Assurance manual. Pulsar's Quality Assurance Manual encompasses the requirements of MIL-I-45208 (Inspection Systems), MIL-Std-45662 (Calibration of Test Equipment) and MIL-Std-105 (Material Controls).
![]() |
![]() |
![]() |
![]() |